Saved calculations: 

INPUTS
 
Liquid flow rate ml
Vapour flow rate mv
Liquid density ρl
Vapour density ρv
Liquid hold-up time τl
 
OUTPUTS
 
Liquid volumetric flow rate Ql 0.20
Vapour volumetric flow rate Qv 800.00
Mixture density ρmix 1.50
Separation factor Sf 0.0071
Separator sizing factor K 0.0795
Maximum vapour velocity uvapmax 2.247
Minimum separation area required Amin 0.09889
Minimum separator diameter Dmin 0.355
Maximum inlet nozzle velocity unozmax 99.61
Minimum inlet nozzle velocity unozmin 59.77
Maximum inlet nozzle diameter dinlet max 0.069
Recommended inlet nozzle size dinlet 3 inch
Liquid hold-up volume Vl 0.017
Liquid height hl 0.105
Vapour height above centre line of inlet nozzle hvabove 1.200
Vapour height below centre line of inlet nozzle hvbelow 0.450
 
Vessel height tan to tan L 1.755
Recommended separator diameter Dsep 0.450
Vessel L:D L:D 3.90
 


Save New Calculation

Please enter a filename and description for this calculation.

Filename: 

Description: